 400 W Single Vout Series
Technical Specification
Industrial Grade AC/DC Power Supply With PFC
85-264 Vrms Input Voltage 12/24/36/48 V Semi-Regulated Output 400 W Output Continuous 500 W Output Transient Up to 91 % Full Load Efficiency
400 W Open Frame
Configurations
*400WEncasedorOpenFrame *800WEncasedFlatorStacked *1200WEncasedFlatorStacked 400 W Encased
1200 W Encased Stacked
800 W Encased Flat
400 W Single Vout Series Features * * * * * * * * High efficiency (91% for 48 VOUT Model at 400 W) Universal input voltage range Semi-regulated output for bus stability Parallel operation supported Integral fan cooling with speed control Active PFC; EN61000-3-2 compliant Low leakage; EN60601-1 compliant Low noise; EN55011 / EN55022 Class B compliant
Phone 1-888-567-9596
* Over-current, over-voltage, and over-temp protection * DC Power Good / AC Power Good signals * Remote enable input * Fan status output / Fan enable input * Small size: 3" x 5" x 1.45" (open frame) * RoHS 6/6 compliant * 5 V (250 mW) standby output
Product # AQ0400IUxx Series
www.synqor.com
Doc.# 005-005052 Rev. A
09/08/08
Page 1
Technical Specification
All specifications typical with TA = 25 C, unless otherwise specified.
MAIN OUTPUT SPECIFICATIONS Output power (continuous) 85-132/170-264 Vrms (5 s transient) 85-132/170-264 Vrms 132-170 Vrms Nominal DC output 12 Vout voltage (at 250W) 24 Vout (Semi-regulated) 36 Vout 48 Vout Efficiency (see figs. 3 - 10) 12 48 12 48 12 24 Maximum load capacitance 12 24 36 48 Output ripple voltage Hold-up time (to -20%) Vout, Vout, Vout, Vout, 115 115 230 230 Vrms, Vrms, Vrms, Vrms, 400 400 400 400 W W W W 400 W 500 W See Figure 10 12.4 V 25 V 37.5 V 50 V 88% 90% 89% 91% typ. typ. typ. typ.
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
ACuQor 400W Series ELECTRICAL CHARACTERISTICS
GENERAL SPECIFICATIONS Fundamental ripple freq. Audible noise Weight (EA \ EC) (SC \ RC) (UC \ TC) MTBF Input Output Fan speed varies with temp. 500 kHz 250 kHz 39 dBA @ 1 m max.
MIL-217 Demonstrated ISOLATION SPECIFICATIONS Isolation voltage Input to output Input to ground Output to ground Output to ground
343 g (12.1 oz) \ 446 g (15.7 oz) 846 g (29.8 oz) \ 879 g (31 oz) 1224 g (43.2 oz) \ 1298 g (45.8 oz) 343.6 kHours TBD kHours 3000 Vrms 1500 Vrms 500 Vrms 10 M min. See Note 2
Vout / 36 / 48 Vout Vout Vout Vout Vout
16 ms @ 400 W 20 ms @ 400 W 16,000 F 8,000 F 4,000 F 2,000 F 0.5% p-p 5.0% p-p 2 s max.
Insulation resistance Leakage currents
Switching frequency (20 MHz BW) Twice line frequency (at 300W)
ENVIRONMENTAL CHARACTERISTICS Thermal performance Relative humidity Altitude Random vibration Shock EMC CHARACTERISTICS Conducted emissions Line frequency harmonics Voltage fluctuations ESD air ESD contact Radiated immunity Fast transients Line surge immunity Conducted immunity Power freq. mag. field Voltage dip immunity EN55011 and EN55022, FCC part15 EN61000-3-2 EN61000-3-3 EN61000-4-2 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 Level B Class A Clause 5b Level 3 Level 3 Level 3 Level 3 Level 3 Level 3 3 A/m Perf Criteria A, A, B <5% UT 10 ms, 70% UT 500 ms, 40% UT 100 ms Operating ambient (see Figure 9) Non-operating ambient Non-condensing Operating Non-operating 5-500 Hz Half-sine, 10 ms, 3 axes 0 C to +70 C -40 C to +85 C 5-95% RH 10,000 ft max. 30,000 ft max. 0.03 g2/Hz 20 g peak
Turn-on delay Transient response Iout steps from 50-75% At 0.2 A/s Cyclic restart Cyclic operation Over line, load and temperature Always on (See Note 1) Automatic recovery Input Low Voltage Input High Voltage Universal range 115 Vrms @ 400 W 230 Vrms @ 400 W 264 Vrms (cold start) Both AC lines
Overvoltage protection Short circuit protection Total regulation Auxillary Output Thermal protection REMOTE_ENABLE INPUT SPECIFICATIONS AC input voltage Input frequency Input current Power factor Input surge current Internal input fuses
3% typ / 6% max. dev. 100 ms recovery 110-120% 115% rated Iout 6.0% 5 V @ 50 mA +125 C (PCB Temp) 0.45 V (max) 4.15 V (min) 85-264 Vrms 47-63 Hz 4 Arms 2 Arms >0.98 40 A max. 6.3 A
SAFETY AGENCY CERTIFICATIONS (pending) All certification marks appear on individual unit labels. UL60950 IEC/EN 60950 CE Marked cUL CSA Standards
NOTES: 1. Derate 1 mA per C above 50 C ambient temperature. 2. Leakage currents: AC Leakage Current from Input to Earth AC Line Connection Normal Open Neutral Condition Fault 400 A 200 A 200 A 800 A 400 A 400 A
240 V L-N, 1 phase ACuQor Typical at 110% nominal input 208 V L-L, 120 V L-N, 1 of 3 phases voltage 60 Hz 240 V L-N-L, 120 V L-N, split phase
Product # AQ0400IUxx Series
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005052 Rev. A
09/08/08
Page 2
Technical Specification
EFFICIENCY, DERATING, AND VOUT DROOP CURVES
100 95 90
14.0 13.5 13.0
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
Output Voltage (V)
115 Vrms 230 Vrms 0 100 200 300 400 500
Efficiency (%)
12.5 12.0 11.5 11.0 10.5 10.0 0 4 8 12 16 20 24 28 32 36
85 80 75 70 65
Output Power (W)
Output Load (A)
Figure 1: 12 VOUT efficiency curves.
Figure 2: 12 VOUT droop characteristic.
100 95 90
28 27 26
Output Voltage (V)
115 Vrms 230 Vrms 0 100 200 300 400 500
Efficiency (%)
25 24 23 22 21 20 0 2 4 6 8 10 12 14 16 18
85 80 75 70 65
Output Power (W)
Output Load (A)
Figure 3: 24 VOUT efficiency curves.
Figure 4: 24 VOUT droop characteristic.
100 95 90
42
40
Output Voltage (V)
115 Vrms 230 Vrms 0 100 200 300 400 500
Efficiency (%)
38
85 80 75 70 65
36
34
32
30 0 2 4 6 8 10 12
Output Power (W)
Output Load (A)
Figure 5: 36 VOUT efficiency curves.
Product # AQ0400IUxx Series Phone 1-888-567-9596
Figure 6: 36 VOUT droop characteristic.
www.synqor.com Doc.# 005-005052 Rev. A 09/08/08 Page 3
Technical Specification
EFFICIENCY, DERATING, AND VOUT DROOP CURVES
100 95 90
54
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
52
Output Voltage (V)
115 Vrms 230 Vrms 0 100 200 300 400 500
Efficiency (%)
50
85 80 75 70 65
48
46
44
42 0 1 2 3 4 5 6 7 8 9
Output Power (W)
Output Load (A)
Figure 7: 48 VOUT efficiency curves.
Figure 8: 48 VOUT droop characteristic.
500
600
400
500
400
Power (W)
300
Power (W)
24 / 36 / 48 V with Fan Enabled 12 V with Fan Enabled
300
200
200 Transient 100 Continuous
100
24 / 36 / 48 V with Fan Disabled 12 V with Fan Disabled
0 0 10 20 30 40 50 60 70 80
0 85
132
170
264
Ambient Temperature (C)
Input AC Voltage (VRMS)
Figure 9: Continuous power derating curve in natural convection.
Figure 10: Rated output power vs Input AC Voltage.
Product # AQ0400IUxx Series
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005052 Rev. A
09/08/08
Page 4
Technical Specification
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
MECHANICAL DRAWINGS (1 Module Open Frame Version -- E Package Type)
Front
Back
Top
Right
Bottom
MECHANICAL DRAWINGS (1 Module Encased Version -- E Package Type)
Top Right Bottom Front
Back
NOTES (applies to all mechanicals) 1)Recommendedscrewtighteningtorqueof6in.lbs 2)Undimensionedcomponentsareshownforvisualreferenceonly 3)Alldimensionsininches[mm] Tolerances: x.xxin0.02 x.xxxin0.010
Product # AQ0400IUxx Series Phone 1-888-567-9596 www.synqor.com Doc.# 005-005052 Rev. A 09/08/08 Page 5
Technical Specification
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
MECHANICAL DRAWINGS (2 Modules Flat Version -- R Package Type)
Product # AQ0400IUxx Series
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005052 Rev. A
09/08/08
Page 6
Technical Specification
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
MECHANICAL DRAWINGS (2 Modules Stacked Version -- S Package Type)
Product # AQ0400IUxx Series
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005052 Rev. A
09/08/08
Page 7
Technical Specification
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
MECHANICAL DRAWINGS (3 Modules Flat Version -- T Package Type)
Product # AQ0400IUxx Series
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005052 Rev. A
09/08/08
Page 8
Technical Specification
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
MECHANICAL DRAWINGS (3 Modules Stacked Version -- U Package Type)
Product # AQ0400IUxx Series
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005052 Rev. A
09/08/08
Page 9
Technical Specification
CONNECTOR DETAILS
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
OUTPUT CONNECTOR PINOUT (top side) Pin 1 FAN_GOOD Open collector with internal 5V pullup. See Figure A. Pulsed low on fan failure, 100ms, 50% duty. Short to VOUT(-) to disable fan. Open collector with internal 5V pullup. See Figure B. Pulled low on AC power dropout. Open collector with internal 5V pullup. See Figure B. Pulled low during startup ramp and within 5 C of temperature shutdown threshold. 5 V @ 50 mA available whenever AC power is applied. Positive Output Voltage. Positive Output Voltage. Positive Output Voltage. Positive Output Voltage. Reserved for future use. Reserved for future use. Logic input. See Figure C. Pull high to enable main output. Negative Output Voltage. Negative Output Voltage. Negative Output Voltage. Negative Output Voltage. Negative Output Voltage.
VOUT(-) 10 Ohms AC_POWER_GOOD or DC_POWER_GOOD 0.1 F 2N3904 From AC/DC Monitor Circuitry 1N4148 5V_STANDBY
Pin 2 Pin 3
AC_POWER_GOOD DC_POWER_GOOD
Figure A: Fan status output / Fan enable input interface circuitry.
Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9
5V_STANDBY VOUT(+) VOUT(+) VOUT(+) VOUT(+) Reserved
Pin 10 Reserved Pin 11 REMOTE_ENABLE Pin 12 VOUT(-) Pin 13 VOUT(-) Pin 14 VOUT(-) Pin 15 VOUT(-) Pin 16 VOUT(-)
5k
Figure B: Power good interface circuitry.
12 V OUTPUT CONNECTOR PINOUT (bottom side) Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 VOUT(+) VOUT(+) VOUT(+) VOUT(+) VOUT(-) VOUT(-) VOUT(-) VOUT(-) Positive Output Voltage. Positive Output Voltage. Positive Output Voltage. Positive Output Voltage. Negative Output Voltage. Negative Output Voltage. Negative Output Voltage. Negative Output Voltage
VOUT(-) REMOTE_ENABLE 5V_STANDBY 10 Ohms
5V_STANDBY
5k 0.1 F 10k
To Enable Circuitry
Figure C: Remote enable interface circuitry.
MATING CONNECTORS Connector OUTPUT (16 pins) INDIVIDUAL INPUT CONNECTOR PINOUT Pin 1 Pin 3 Pin 5 Ground AC Neutral AC Line 12V_OUTPUT (8 pins) INPUT Type Molex 430251600 Molex 436450800 JST VHR-5N Contact Molex 430300008* Molex 430300008* JST SVH-41T-P1.1
* Each contact rated for a maximum of 5.5 A.
Phone 1-888-567-9596 www.synqor.com Doc.# 005-005052 Rev. A 09/08/08 Page 10
Product # AQ0400IUxx Series
Technical Specification
PARALLEL OPERATION - MULTIPLE UNITS
Chassis configurations for Parallel Units ACuQor units are available either open-frame or pre-mounted at the factory. Up to 3 units can be mounted into a chassis, in either side-by-side or stacked configurations. For a complete list of options, see the "Part Numbering System" table on the last page, under "Package Type", along with the Mechanical Drawings pages. Only side-by-side configurations can be populated with 500W units, since each includes a thermal pad underneath. Interconnection of Parallel Units ACuQor units mounted in 2 and 3 unit chassis are not connected together. This allows the physical routing and connectivity of the external wiring to be customized to each application. The following table summarizes the recommended wiring to operate multiple units in parallel:
Output Connector Signal Suggested Connection
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
Specifications of Parallel Units As a rule, units wired in parallel behave the same as single units. Any specification will remain unchanged that is expressed in units of voltage, time, frequency, or efficiency. Specifications expressed in terms of power, current, or capacitance, should be scaled by the number of units wired in parallel. ACuQor units are individually calibrated at the factory, so that the output voltage vs. output current characteristic is always consistent (see Vout droop characteristic figures). As such, multiple units will share output current accurately. Full current is guaranteed from a bank of multiple units wired in parallel.
Behavior with Multiple Units
REMOTE_ENABLE FAN_GOOD AC_POWER_GOOD DC_POWER_GOOD VOUT(+), VOUT(-) 12V_STANDBY* 5V_STANDBY
Wire in parallel " " " " " Do not wire in parallel
Inputs activated simultaneously Wired-OR outputs - can be pulled low by any unit during an abnormal condition. " " Built-in droop characteristic ensures graceful current sharing. " Fully regulated characteristic does not support current sharing. If placed in parallel, only the output with the highest set-point will drive current.
*Note: Triple output models only.
Product # AQ0400IUxx Series
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005052 Rev. A
09/08/08
Page 11
Technical Specification
INSTALLATION INSTRUCTIONS
General:ACuQorAC/DCpowersuppliesareintendedforuse as components in industrial equipment. ACuQor units must be properly installed within end use equipment before they can be safely applied as described in this document. The suitability of theACuQor/equipmentcombinationmustbeverifiedthroughend productinvestigation. Mounting:RefertotheMechanicalDrawingssection.ACuQor unitsareprovidedwiththreadedstainless-steelstand-offsorinserts formounting.Thismountinghardwareisinternallyconnectedto the input connector protective-earth terminal for functional-earth EMCcontrol.Anyorientation(vertical,horizontal,etc.)maybe used.Adequateairspaceshouldbeprovidedoverthefanintake (top) and exhaust (sides) to allow for exchange of cooling air. ACuQorisdesignedforapollutiondegree2environment.The suitabilityoftheenclosedACuQormechanicalassembliesmustbe verifiedthroughendproductinvestigation. Encased models: A minimum of 5 mm electrical clearance shouldbeallowedfromtheconnectorendsofencasedmodels. Input: Refer to the Connector Details section for input connectorwiring.ACuQorproductsrequireasinglephaseACpower sourceof100-240V50/60Hznominal.Refertonameplatelabel for input current ratings. A protective-earth connection is also required. Minimum wire size of 18 AWG (0.8mm2) is recommended.BothsidesoftheAClineareinternallyfused(seetable forspecificmodels).Thesefusesarenotuserreplaceable.
MODEL AQ0300 AQ0400 AQ0500 Input Fuses (in Both AC Lines) Littelfuse6.3A250V21606.3XEP Littelfuse6.3A250V21606.3XEP Littelfuse10.0A250V216010XEP Fuses Total 2 2 2
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
Output: Refer to the Connector Details section for output connector wiring and signal I/O functionality. Refer to nameplate label for output current ratings. Main DC output (Vout+, Vout-) pins should use 20 AWG (0.5mm2) wire size. Individual main outputpinsshouldnotbeloadedtomorethan5.5A.Forcurrents greaterthan5.5A,multiplemainoutputpins/wiresmustbeused inparallel.AllsignalI/OpinsarereferencedtoVout-. EMC:ACuQorproductshavebeentestedtotheEMCspecificationslistedintheElectricalCharacteristicssection.However,end useequipmentmustbetestedtoverifyEMCcompliance. Hipot Testing: ACuQor products are rated for Hipot testing levels of 1500 Vac input to protective-earth, 500 Vac output to protective-earth, and 3000 Vac input to output. When performing the 3000 Vac input to output test, the test voltage must be balanced evenly 1500 Vac input and output to protective-earth. Two oppositely phased test voltage sources or a single test voltagesourcewithexternalbalancingimpedances(capacitors)may beusedtopreventoverstressinginputoroutputtoprotective-earth insulationperIEC/ENC60950-1.
Product # AQ0400IUxx Series
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-005052 Rev. A
09/08/08
Page 12
Technical Specification
PART NUMBERING SYSTEM
AC Input: 85-264 VRMS DC Output: 12/24/36/48V Semi-reg. Power: 400 W Series Grade: Industrial
The part numbering system for SynQor's ACuQor AC/DC power supplies follows the format shown in the table below. Notallcombinationsmakevalidpartnumbers,pleasecontactSynQorforavailability.
Family Output Power
0300: 300 W 0400: 400 W 0500: 500 W 0600: 600 W (2 x 300 W) 0800: 800 W (2 x 400 W) 0900: 900 W (3 x 300 W) 1000: 1000 W (2 x 500 W) 1200: 1200 W (3 x 400 W) 1500: 1500 W (3 x 500 W)
Grade
Range
Output Voltage
(xx=Standard; xT=Triple) 12: 12 V 1T: 12 V / 5 & 12 V STBY 24: 24 V 2T: 24 V / 5 & 12 V STBY 36: 36 V 3T: 36 V / 5 & 12 V STBY 48: 48 V 4T: 48 V / 5 & 12 V STBY
Package Type
(Correlates to Output Power)
Thermal Design
Options
AQ ACuQor series of ac-dc semi-regulated output power supplies
I: industrial
U: universal (85-264 VRMS)
E: 1 unit (3" x 5") R: 2 units; flat S: 2 units; stacked T: 3 units; flat U: 3 units; stacked
A: open frame C: encased Q: encased only
Industrial Grade: IND: Industrial
ACCESSORIES
Example: AQ0400IU24EAIND
SynQoroffersaseriesofassembliesthatcanbeorderedaccordingtothetablebelow.Mechanicaldrawingsfortheseaccessoriesare availablefordownloadinpdfformatfromtheSynQorwebsite.
Part Number
AQ-CBL-INPUT1C AQ-CBL-OUT1C AQ-CBL-OUT1CD AQ-CBL-OUT2C AQ-CBL-OUT2CD AQ-INSUL1M AQ-EVAL-PRL3
Description
Input mating cable with pre-stripped wire ends (36" long). Output mating cable with pre-stripped wire ends (18" long). Same as AQ-CBL-OUT1C with an additional 8-pin connector. Output mating cable with connectors on both ends (18" long). Same as AQ-CBL-OUT2C with an additional 8-pin connector. Single module bottom-side Mylar insulator for open frame mounting. Evaluation board for up to three paralleled modules.
APPLICATION NOTES
AvarietyofapplicationnotesandtechnicalwhitepaperscanbedownloadedinpdfformatfromtheSynQorwebsite.
PATENTS
SynQorholdsthefollowingpatents,oneormoreofwhichmightapplytothisproduct: 5,999,417 6,222,742 6,545,890 6,594,159 6,731,520 6,894,468 6,927,987 7,050,309 7,072,190 7,119,524 7,269,034 7,272,021
6,577,109 6,896,526 7,085,146 7,272,023
Contact SynQor for further information:

Phone: TollFree: Fax: E-mail: Web: Address:
978-849-0600 888-567-9596 978-849-0602 power@synqor.com www.synqor.com 155SwansonRoad Boxborough,MA01719,USA
Phone 1-888-567-9596
Warranty:SynQoroffersatwo(2)yearlimitedwarranty.CompletewarrantyinformationislistedonourwebsiteorisavailableuponrequestfromSynQor. Limitation on use: SynQor's products are not authorized for use and should not be used, without the specific prior written approval of an authorized officer of SynQor makingspecificreferencehereto,inanylifesupportsystem,nuclearfacilityorapplication,aircraftcontrolapplicationoranyotherapplicationinwhichfailureoftheproduct couldreasonablyresultinharmtolife,propertyortheenvironment. InformationfurnishedbySynQorisbelievedtobeaccurateandreliable.However, noresponsibilityisassumedbySynQorforitsuse,norforanyinfringementsofpatents orotherrightsofthirdpartieswhichmayresultfromitsuse.Nolicenseisgrantedby implicationorotherwiseunderanypatentorpatentrightsofSynQor.
Doc.# 005-005052 Rev. A 09/08/08 Page 13
Product # AQ0400IUxx Series
www.synqor.com


▲Up To Search▲   

 
Price & Availability of AQ0400IU12EAIND

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X